Immediate breast reconstruction using titanised mesh
https://doi.org/10.17650/1994-4098-2020-16-2-13-18
Abstract
Additional covering of the lower pole with allomaterial or its synthetic analogues during immediate breast reconstruction is being performed at the N. N. Petrov National Medical Research Oncology Center, Ministry of Health of Russia, for last 7 years. Initially, epidermal flap was the only option for lower pole coverage; later acellular dermal matrix was used as part of clinical approbation. Average complication rate ranges from 20–35 % due to blood circulatory (supply) disorders.
Since 2018, a titanised mesh been used as an additional coverage of the lower pole in the department of breast tumors. Through coating characteristics and its structure the frequency of fatal complications significally decreased.
About the Authors
P. V. KrivorotkoRussian Federation
68 Leningradskaya St., Pesochnyy Settlement, Saint Petersburg 197758
41 Kirochnaya St., Saint Petersburg 191015
R. S. Pesotskyy
Russian Federation
68 Leningradskaya St., Pesochnyy Settlement, Saint Petersburg 197758
K. Yu. Zernov
Russian Federation
68 Leningradskaya St., Pesochnyy Settlement, Saint Petersburg 197758
A. A. Bessonov
Russian Federation
68 Leningradskaya St., Pesochnyy Settlement, Saint Petersburg 197758
E. K. Zhiltsova
Russian Federation
68 Leningradskaya St., Pesochnyy Settlement, Saint Petersburg 197758
A. V. Komyakhov
Russian Federation
68 Leningradskaya St., Pesochnyy Settlement, Saint Petersburg 197758
T. T. Tabagua
Russian Federation
68 Leningradskaya St., Pesochnyy Settlement, Saint Petersburg 197758
K. S. Nikolaev
Russian Federation
68 Leningradskaya St., Pesochnyy Settlement, Saint Petersburg 197758
K. Yu. Rychagov
Russian Federation
68 Leningradskaya St., Pesochnyy Settlement, Saint Petersburg 197758
V. G. Ivanov
Russian Federation
68 Leningradskaya St., Pesochnyy Settlement, Saint Petersburg 197758
L. P. Gigolaeva
Russian Federation
68 Leningradskaya St., Pesochnyy Settlement, Saint Petersburg 197758
O. A. Ivanova
Russian Federation
68 Leningradskaya St., Pesochnyy Settlement, Saint Petersburg 197758
G. A. Dashyan
Russian Federation
68 Leningradskaya St., Pesochnyy Settlement, Saint Petersburg 197758
V. V. Semiglazov
Russian Federation
68 Leningradskaya St., Pesochnyy Settlement, Saint Petersburg 197758
A. S. Emelyanov
Russian Federation
68 Leningradskaya St., Pesochnyy Settlement, Saint Petersburg 197758
S. S. Yerechshenko
Russian Federation
68 Leningradskaya St., Pesochnyy Settlement, Saint Petersburg 197758
A. S. Shishova
Russian Federation
68 Leningradskaya St., Pesochnyy Settlement, Saint Petersburg 197758
E. T. Munaeva
Russian Federation
68 Leningradskaya St., Pesochnyy Settlement, Saint Petersburg 197758
Z. A. Aseeva
Russian Federation
68 Leningradskaya St., Pesochnyy Settlement, Saint Petersburg 197758
V. F. Semiglazov
Russian Federation
68 Leningradskaya St., Pesochnyy Settlement, Saint Petersburg 197758
41 Kirochnaya St., Saint Petersburg 191015
References
1. Situation with cancer care in Russia in 2017. Ed. by V.V. Starinskiy, A.D. Kaprin, G.V. Petrova. Moscow: P. Herzen Moscow Oncology Research Institute — a branch of the National Medical Research Center of Radiology, Ministry of Health of Russia, 2018. (In Russ.).
2. Novikov S., Krzhivitskii P., Kanaev S. et al. SPECT-CT localization of axillary sentinel lymph nodes for radiotherapy of early breast cancer. Rep Pract Oncol Radiother 2019;24(6):688–94. DOI: 10.1016/j.rpor.2019.10.003.
3. ASoB S. Performance and practice guidelines for mastectomy. 2015. Available at: https://www.breastsurgeons.org/statements/guidelines/PerformancePracticeGuidelines_Mastectomy.pdf.
4. Dieterich M., Reimer T., Dieterich H. et al. A short-term follow-up of implant based breast reconstruction using a titanium-coated polypropylene mesh (TiLOOP ® Bra). Eur J Surg Oncol 2012;38(12):1225–30. DOI: 10.1016/j.ejso.2012.08.026.
5. Dieterich M., Faridi A. Biological matrices and synthetic meshes used in implant-based breast reconstruction — a review of products available in Germany. Geburtsh Frauenheilk 2013;73:1100–6. DOI: 10.1055/s-0033–1350930.
6. Dieterich M., Dieterich H., Timm S. et al. Using a titanium-coated polypropylene mesh (TiLOOP ® Bra) for implantbased breast reconstruction: case report and histological analysis. Arch Gynecol Obstet 2012;286(1):273–6. DOI: 10.1007/s00404-012-2253-2.
7. Breast Reconstruction: art, science, and new clinical techniques. Ed. by M. A. Shiffman. Springer, 2015.
8. Breuing K. H., Colwell A. S. Inferolateral AlloDerm hammock for implant coverage in breast reconstruction. Ann Plast Surg 2007;59(3):250–5. DOI: 10.1097/SAP.0b013e31802f8426.
9. Kamaletdinov I. F., Ismagilov A. Kh. Choosing an optimal method of inframammary fold restoration in breast reconstructive surgery. Plasticheskaya khirurgiya i esteticheskaya meditsina = Plastic Surgery and Aesthetic Medicine 2019;(2):5–12. (In Russ.). DOI: 10.17116/plast.hirurgia20190215.
10. Dieterich M., Paepke S., Zwiefel K. et al. Implant-based breast reconstruction using a titanium-coated polypropylene mesh (TiLOOP ® Bra): a multicenter study of 231 cases. Plast Reconstr Surg 2013;132(1): 8e—19e. DOI: 10.1097/PRS.0b013e318290f8a0.
11. Gschwantler-Kaulich D., Schrenk P., Bjelic-Radisic V. et al. Mesh versus acellular dermal matrix in immediate implant-based breast reconstruction a prospective randomized trial. Eur J Surg Oncol 2016;42(5):665–71. DOI: 10.1016/j.ejso.2016.02.007.
12. O’Halloran N., Lowery A., Curran C. et al. A review of the impact of neoadjuvant chemotherapy on breast surgery practice and outcomes. Clin Breast Cancer 2019;19(5):377–82. DOI: 10.1016/j.clbc.2019.04.011.
13. Vandeweyer E., Deraemaecker R., Nogaret J. M., Hertens D. Immediate breast reconstruction with implants and adjuvant chemotherapy: a good option? Acta Chir Belg 2003;103(1):98–101. DOI: 10.1080/00015458.2003.11679374.
14. Dinç S. Ç. Effects of TiLOOP ® Bra mesh on radiotherapy dose distribution. Turk J Oncol 2019;34(3). DOI: 10.5505/tjo.2019.1966.
15. Camacho C., Pujades M. C., PerezCalatayud J. et al. Impact of the TiLOOP® Bra mesh in CT images and dose delivery in breast radiotherapy. J Appl Clin Med Phys 2012;13(2):3667. DOI: 10.1120/jacmp.v13i2.3667.
Review
For citations:
Krivorotko P.V., Pesotskyy R.S., Zernov K.Yu., Bessonov A.A., Zhiltsova E.K., Komyakhov A.V., Tabagua T.T., Nikolaev K.S., Rychagov K.Yu., Ivanov V.G., Gigolaeva L.P., Ivanova O.A., Dashyan G.A., Semiglazov V.V., Emelyanov A.S., Yerechshenko S.S., Shishova A.S., Munaeva E.T., Aseeva Z.A., Semiglazov V.F. Immediate breast reconstruction using titanised mesh. Tumors of female reproductive system. 2020;16(2):13-18. (In Russ.) https://doi.org/10.17650/1994-4098-2020-16-2-13-18