Capabilities of percutaneous biopsy methods to preoperatively verify breast microcalcinates
https://doi.org/10.17650/1994-4098-2011-0-2-16-21
Abstract
About the Authors
N. V. PonedelnikovaRussian Federation
X-Ray Diagnosis Department
G. P. Korzhenkova
Russian Federation
X-Ray Diagnosis Department
V. P. Letyagin
Russian Federation
Breast Tumor Surgery Department
A. V. Petrovsky
Russian Federation
Radiosurgery Department
Ya. V. Vishnevskaya
Russian Federation
Human Tumor Pathoanatomy Department
E. Yu. Kuzmicheva
Russian Federation
X-Ray Diagnosis Department
References
1. Рожкова Н.И., Меских Е.В. Рентгенологическая и сонографическая семиотика доброкачественных и злокачественных заболеваний молочной железы. Клиническая маммология. Тематический сборник. Под ред. В.П. Харченко, Н.И. Рожковой. М.: СТРОМ, 2005; с. 97–138.
2. Lee C.H., Egglin T.K., Philpotts L.E. et al. Cost-effectiveness of stereotactic core needle biopsy: analysis by means of mammographic findings. Radiology 1997;202:849–54.
3. Leifland K., Lagerstedt U., Svane G. Comparison of stereotactic fine needle aspiration cytology and core needle biopsy in 522 non-palpable breast lesions. Acta Radiol 2003;44(4):387–91.
4. Liberman L., Dershaw D.D., Rosen P.P. et al. Percutaneous removal of malignant mammographic lesions at stereotactic vacuum-assisted biopsy. Radiology 1998;206:711–5.
5. Parker S.H., Burbank F. A practical approach to minimally invasive breast biopsy. Radiology 1996;200:11–20.
6. Simon J.R., Kalbhen C.L., Cooper R.A. et al. Accuracy and complication rates of US-guided vacuum-assisted core breast biopsy: initial results. Radiology 2000;215:694–7.
7. Meyer J.E., Smith D.N., Di Piro P.J. Stereotactic breast biopsy of clustered microcalcifications with a directional, vacuum-assisted device. Radiology 1997;204:575–6.
8. Reynolds H.E., Poon C.M., Goulet R.J. et al. Biopsy of breast microcalcification using an 11-gauge directional vacuum-assisted device. Am J Roentgenol 1998;171:611–3.
9. Philpotts L.E., Hooley R.J., Lee C.H. Comparison of automated versus vacuum- assisted biopsy methods for sonongraphically guided core biopsy of the breast. Am J Roentgenol 2003;180(2):347–51.
10. Hoorntje L.E., Peeters P.H., Mali W.P. et al. Is stereotactic large-core needle biopsy beneficial prior to surgical treatment in BI-RADS 5 lesions? Breast Cancer Res Treat 2005;90(2):191.
11. Siegmann K.C., Wersebe A., Fischmann A. et al. Stereotactic vacuum-assisted breast biopsy: success, histologic accuracy, patient acceptance and optimizing the BIRADS TM — correlated indication. Rofo 2003;175(1):99–104.
12. Корженкова Г.П. Комплексная рентгено-сонографическая диагностика заболеваний молочной железы. Практическое руководство. М.: СТРОМ, 2004.
13. Фишер У., Баум Ф., Люфтнер-Нагель С. Лучевая диагностика. Заболевания молочных желез. Практическое руководство. Под ред. Б.И. Долгушина. М.: МЕДпресс- информ, 2009.
14. Ермилова В.Д. Патоморфологическая характеристика опухолей и опухолеподобных заболеваний молочной железы. Клиническая маммология. Под ред. Е.Б. Камповой-Полевой, С.С. Чистякова. М.: ГЭОТАР-Медиа, 2006; с. 17–48.
Review
For citations:
Ponedelnikova N.V., Korzhenkova G.P., Letyagin V.P., Petrovsky A.V., Vishnevskaya Ya.V., Kuzmicheva E.Yu. Capabilities of percutaneous biopsy methods to preoperatively verify breast microcalcinates. Tumors of female reproductive system. 2011;(2):16-21. (In Russ.) https://doi.org/10.17650/1994-4098-2011-0-2-16-21